Chunk #6 — Materials and Methods — EEG recordings

Source
Default Mode Network alterations in alexithymia: an EEG power spectra and connectivity study.
Embedded
yes

Text

EEG was recorded by means of a Micromed System Plus digital EEGraph (Micromed© S.p.A., Mogliano Veneto, TV, Italy). EEG montage included 19 standard scalp leads positioned according to the 10–20 system (recording sites: Fp1, Fp2, F7, F3, Fz, F4, F8, T3, C3, Cz, C4, T4, T5, P3, Pz, P4, T6, O1, O2), Electrooculography (EOG) and Electrocardiography (EKG). The reference electrodes were placed on the linked mastoids. Impedances were kept below 5 KΩ before starting the recording and checked again at the end of the experimental recording. Sampling frequency was 256 Hz; A/D conversion was made at 16 bit; pre-amplifiers amplitude range was ±3200 μV and low-frequency pre-filters were set at 0.15 Hz. The following band-pass filters were used: high frequency filters (HFF) = 0.2 Hz; low frequency filters (LFF) = 128 Hz.