Chunk #18 — Results — Behavior — Accuracy and error type count

Source
Electrophysiological evidence of enhanced performance monitoring in recently abstinent alcoholic men.
Embedded
yes

Text

The groups did not differ in the detection or matching accuracy (p = 0.332; without using years of education as a covariate p = 0.454). All subjects made more errors of omission than commission [F (1, 26) = 5.92; p = 0.022], but there were no group differences in the number of either type of error committed (p = 0.523; Table 2.) There was neither a significant difference between the number of response errors made with the right (S response) and the left (H response) hand (p = 0.093) nor a group difference in these measures (p = 0.977). Table 2Accuracy and error type countGroupAccuracyError typesOmissionCommissionControlMean0.845028SD0.042518AlcoholicMean0.864127SD0.092931