Chunk #15 — Methods — EEG Data Acquisition and Preprocessing

Source
Deficient Event-Related Theta Oscillations in Individuals at Risk for Alcoholism: A Study of Reward Processing and Impulsivity Features.
Embedded
yes

Text

Identical experimental procedures and EEG acquisition systems were used at all neurophysiology collection sites of COGA [73,74] with high inter-laboratory consistency in recordings [82–85]. Subjects were seated comfortably 1 m from a monitor in a dimly lit sound-attenuated RF-shielded booth (Industrial Acoustics, Inc., Bronx, NY, USA), and wore a 61-channel electrode cap (Electro-Cap International, Inc., Eaton, OH, USA) based on the Extended 10–20 Systems [86–88] (Fig 2), with a reference electrode at the tip of the nose and with a ground electrode at the forehead. The electrooculogram (EOG) was recorded by a supraorbital vertical electrode and by a horizontal electrode on the external canthus of the left eye. Electrode impedances were maintained below 5 kΩ. Electrical activity was amplified 10,000 times using SynAmps2 amplifiers (Compumedics USA, Charlotte, NC) and was recorded continuously over a bandwidth of DC–100.0 Hz on a Neuroscan system (Versions 4.3–4.5; Compumedics USA, Charlotte, NC) at the sampling rate of 500 Hz. The entire EEG data was resampled offline to 256 Hz for the analyses. In this study, only ‘loss 50’ (representing the loss condition) and ‘gain