MRI scans were acquired using the Philips Medical Systems (Best, Netherlands) Ingenia wide-bore dStream 3T MRI scanner, with a 32-channel receive head coil. Single shot gradient-echo echoplanar imaging (EPI) was used for acquiring fMRI data. The fMRI acquisition parameters were: SENSE in-plane acceleration factor 1.5, multiband factor 3, repetition time 1625 ms, echo time 30 ms, flip angle 52°, field of view 240 mm (anterior-to-posterior) × 240 mm (left-to-right) × 125.70 mm (foot-to-head), in-plane resolution 2.5 mm × 2.5 mm, 45 axial slices, slice thickness 2.5 mm, interslice gap 0.30 mm, 420 repetitions per run after 12 dummy acquisitions, and total duration 11 minutes 22 seconds. Subjects completed the resting state fMRI scan with eyes open while looking at a black fixation cross on a white screen. Greater detail regarding MRI acquisition parameters is available in Supplementary File.