The sodium and potassium currents were acquired in voltage clamp mode. Cells were held at −60 mV, and voltage steps of 400 ms were made in the range of −90 to 80 mV. Currents were generally normalized by the cell capacitance. In the Li measurements, no normalization was performed, because of the large change in cell capacitance caused by the Li treatment.