epochs with DC shift/drift involving voltage steps higher than 75 mV between any two adjacent sampling points; and (v) removal of possible EOG contaminated epochs if any data point was beyond the threshold of ± 100 μV or if the difference between lowest and highest amplitude within the epoch was 200 μV. Artifact free 50 random epochs were selected for each participant in each group for the functional connectivity analysis.