Chunk #16 — MATERIALS AND METHODS — EEG Analysis

Source
Event-related oscillations versus event-related potentials in a P300 task as biomarkers for alcoholism.
Embedded
yes

Text

Artifacts were removed using the Gratton and Coles method implemented in BVA (Gratton et al., 1983). Data were then bandpass filtered between 0.5 Hz and 30Hz3 using a zero phase lag filter with a 48 dB/octave roll-off. Stimulus-locked trials were extracted for all instances where there was a correct behavioral response, for each of the three experimental conditions (target, rare non-target and standard non-target), with each trial comprising 450ms of data pre-stimulus and 1300ms post-stimulus4. The response window for correct responses on target trials was 800 ms. Data for the ERP analysis were baseline corrected using the 100ms pre-stimulus interval5. Any trials containing out of range voltages (± 75 μV) were rejected as artifacts and excluded from further processing. All further processing was applied to the data from the target condition only.