Chunk #23 — Methods — Measurements and data analysis — EEG data acquisition

Source
The relationship of Asperger's syndrome to autism: a preliminary EEG coherence study.
Embedded
yes

Text

rate, 1 to 100 Hz band-pass), and one other amplifier type was utilized for 11 control subjects (Neuroscan™; Compumedics Neuroscan, Charlotte, NC, USA; 500 Hz sampling rate, 0.1 to 100 Hz band-pass). Data from these two amplifiers, sampled at other than 256 Hz, were interpolated to the rate of 256 Hz by the BESA 3.5™ software package (BESA GmbH, Gräfelfing, Germany). As the band-pass filter characteristics differed among the three EEG machines, frequency response sweeps were performed on all amplifier types to permit modification of data recorded to be equivalent across amplifiers. This was accomplished by utilizing special software developed in-house by the first author using forward and reverse Fourier transforms [42].